pump pulley

Greg/sd

New Member
I need to know what size pump pulley to use to get my pump to turn at 1450 rpm. my engine pulley is a 3.4 size. any help thanks
 

Glenn Clark

New Member
Lets see...

1450 div. by 3600 = .4027...3.4 x .4027 = 1.37

To get the rpm's down you would need a engine pully around 1.37" if the pumps pully is 3.4"...Is there enough room to go with a larger pulley on the pump? 1.37" is awfully small. :cool:
 

Mark

Moderator / Sponsor
It gets a little confusing sometimes!

I had to scratch my head for a second or two!

To determine pulley / sheave size start with the "known" engine speed and engine sheave / pulley size.

3.4 sheave.. engine speed 3200 - 3600 RPM depending on who set it up, and " desired RPM 1450"

Divide driver speed by desired speed of driven: (driver = engine..driven=pump)
3200 divided by 1450 = 2.20........(A 2.2 to 1 ratio)
Next multiply 2.2 by the known size of the driver 3.4
2.2 x 3.4= 6.8

So you would need a sheave / pulley with size of @ 6.8.
:)
 

Attachments

  • ribbon.gif
    ribbon.gif
    3.4 KB · Views: 105
H

Hotwaterwizard

Guest
If you want me to send you a worksheet I made up just Email me or go to my web page. Pumps 101
 

Our Sponsors