Recent content by Streetdoc432

  1. Streetdoc432

    Hello hello

    Welcome Michael
  2. Streetdoc432

    Hello

    Welcome Greg. Wow, you are moving from one extreme to another!
  3. Streetdoc432

    How to Remove Chewing Gum from Concrete

    Tip learned from experience... Hot pressure washer works best, use a plastic scraper, the steel ones will leave small metal scrapings in the concrete pores & leave rust stains over time.
  4. Streetdoc432

    Battery question

    Thanks guys, I had a gift certificate to O'Reilly's auto parts left over from Christmas. I used that plus my fire department discount to get a Optima marine battery. Cost me the same as an Interstate one. Now I am going to mount a solar conditioner to the top of my tank. Hopefully it will last...
  5. Streetdoc432

    Trailer set up

    Well, I think I figured it out. Last weekend I picked up my new pressure washer. It is 4000/7gpm belt drive. Since it is a dual line skid, I'm not going to be mounting my cold water unit. I will use a 1" line from my buffer tank, and set it up where I can supply from my 3/4" garden hose or...
  6. Streetdoc432

    Battery question

    Thanks Chris, I think there's an Interstate battery store in my town. I will check them out...
  7. Streetdoc432

    Battery question

    I bought a new PW with a 12v burner.. I know ONE of the problems with the 12 v system is not having a strong enough battery to fire the burner, hence frying the igniter module....Do you guys recommend the Optima group 75 gel battery? Or just a generic deep cycle? Thanks! I am planning on leaving...
  8. Streetdoc432

    Trailer set up

    Mark, I just wanted to give you a heartfelt thanks for taking the time out of your day to help me with my newbie questions, knowing I could never come & physically show up at your shop. ( because it would be about a 26 hour drive for me. ) thanks again. True professionalism!
  9. Streetdoc432

    Trailer set up

    Mark, my cold water is 3300/3gpm & my hot water is 3500/5gpm. I have 100' of 3/4" supply. I am thinking of using 1" line from my supply reel to my buffer tank. 1" line to both of my PWs, unloaders dumping back into the tank. I will put a tee inline somewhere so I can winterize when needed. I...
  10. Streetdoc432

    Trailer set up

    I am in the process of setting up my first trailer. I will be using a 275 gallon cube tank, fed by 3/4" hose on a reel. I will have a hot water unit and a cold water unit each with their own HP reel. I will be using the tank as a buffer tank with the unloaders dumping back to the tank. I have a...
  11. Streetdoc432

    Pressure regulating

    Thanks for the help Mark. I have got sooo much to learn. I wish I could find a hot water unit locally that had a higher gpm. Can't afford a new one right now or a higher gpm pump either. Maybe after I get a few more jobs under my belt. Gotta start somewhere.
  12. Streetdoc432

    Pressure regulating

    Thanks Mark. Will it mess up my pump or unloader doing it that way?
  13. Streetdoc432

    Pressure regulating

    I am a newbie with a question for you pros out there. I just bought an Alkota 5000psi / 5 gpm hot water skid. All my equipment I have ( surface cleaner, pole extension ) are rated for 4000 psi. Is it OK to regulate the pressure down with the unloader valve when I use these accessories? My...
  14. Streetdoc432

    Hello Everybody!

    Hello, my name is Sonny, and I'm an alcoholic... Wait, am I at the right place?? Just kidding..My name is Sonny, I am embarking on an adventure to start my own PW service part time. I will be doing pool decks, driveways, sidewalks and refinishing wood decks. I work full time on the fire...
Top